Posts

Showing posts with the label Vibration Sensor (Accelerometer) Calibration for Bearing Monitoring

Control Valve Partial Stroke Testing (PST) for Safety Valves

Practical Procedure · Safety Systems Control Valve Partial Stroke Testing (PST) for Safety Valves Applies to: Emergency shutdown (ESD) valves and safety instrumented function (SIF) final elements  |  Equipment needed: PST-capable positioner/logic solver, position feedback monitoring, coordination with process/operations Full Stroke vs. Partial Stroke — Why PST Exists Tap a tab to see the difference between a full functional test and a partial stroke test, and why PST lets you test without shutting down. Full Stroke Test Partial Stroke Test (PST) ESD Valve — Process Running 0% → 100% → 0% process fully interrupted during test ESD Valve — Process Running ...

Vibration Sensor (Accelerometer) Calibration for Bearing Monitoring

Image
Practical Procedure · Calibration Vibration Sensor (Accelerometer) Calibration for Bearing Monitoring Applies to: Piezoelectric accelerometers and vibration transmitters on rotating equipment (fans, motors, mill bearings) | Equipment needed: Vibration calibrator (reference shaker), multimeter, manufacturer's sensitivity spec sheet Accelerometer Reading Bearing Vibration The sensor converts mechanical vibration into an electrical signal Accelerometer Vibration signal (time domain) The bearing housing vibrates at a frequency and amplitude tied to its mechanical condition. The accelerometer's internal piezoelectric crystal generates a tiny voltage proportional to that vibration, which the transmitter converts into a standard signal for trending — rising amplitude over time is what flags a developing bearing fault long before it fails. Before You Start ...